防爆環(huán)境的劃分:
爆炸性環(huán)境:在大氣條件下,可燃性物質(zhì)以氣體、蒸汽、粉塵、纖維或飛絮的形式與空氣形成的混合物,被點(diǎn)燃后,能夠保持燃燒自行傳播的環(huán)境。
爆炸性氣體環(huán)境:在大氣條件下,可燃性物質(zhì)以氣體或蒸汽的形式與空氣形成的混合物,被點(diǎn)燃后,能夠保持燃燒自行傳播的環(huán)境。
根據(jù)爆炸性氣體環(huán)境出現(xiàn)的頻次和持續(xù)時(shí)間把危險(xiǎn)場所分為0區(qū)、1區(qū)、2區(qū)。
0區(qū):爆炸性氣體環(huán)境連續(xù)出現(xiàn)或頻繁出現(xiàn)或長時(shí)間存在的場所。
1區(qū):正常運(yùn)行時(shí),可能偶爾出現(xiàn)爆炸性氣體環(huán)境的場所。
2區(qū):在正常運(yùn)行中,不可能出現(xiàn)爆炸性氣體環(huán)境,如果出現(xiàn),僅是短時(shí)間存在的場所。
同樣的,對(duì)于粉塵環(huán)境中,也分為了20區(qū)、21區(qū)、22區(qū)
20區(qū):在正常運(yùn)行過程中可燃性粉塵連續(xù)出現(xiàn)或經(jīng)常出現(xiàn),其數(shù)量足以形成可燃性粉塵與空氣混合物和/或可能形成無法控制和極厚的粉塵層的場所及容器內(nèi)部。
21區(qū):在正常運(yùn)行過程中,可能出現(xiàn)粉塵數(shù)量足以形成可燃性粉塵與空氣混合物但未劃入20區(qū)的場所,該區(qū)域包括與充入或排放粉塵點(diǎn)直接相鄰的場所。
22區(qū):在異常情況下,可燃性粉塵云偶爾出現(xiàn)并且只是短時(shí)間存在或可燃性粉塵偶爾出現(xiàn)堆積或可能存在粉塵層并且產(chǎn)生可燃性粉塵空氣混合物的場所。
Understanding of explosion-proof environment

Understanding of explosion-proof environment
Explosive environment: Under atmospheric conditions, a mixture of flammable substances and air in the form of gas, steam, dust, fibers, or fly floes, after being ignited, can maintain an environment in which combustion propagates on its own.
Explosive gas environment: Under atmospheric conditions, a mixture of flammable substances in the form of gas or steam and air, after being ignited, can maintain an environment in which combustion propagates spontaneously.
According to the frequency and duration of explosive gas environment, the hazardous locations are divided into Zone 0, Zone 1, and Zone 2.
Zone 0: A place where explosive gas environment appears continuously or frequently or exists for a long time.
Zone 1: A place where an explosive gas environment may occasionally occur during normal operation.
Zone 2: In normal operation, there is no possibility of an explosive gas environment. If it occurs, it is only a place where it exists for a short time.
Similarly, in the dust environment, it is also divided into 20 zones, 21 zones, and 22 zones
Zone 20: Combustible dust appears continuously or frequently during normal operation, the amount of which is sufficient to form a mixture of combustible dust and air and / or may form an uncontrollable and extremely thick layer of dust and inside the container.
Zone 21: During normal operation, there may be places where the amount of dust is sufficient to form a mixture of combustible dust and air, but it is not zoned into zone 20. This zone includes places directly adjacent to the points where the dust is charged or discharged.
Zone 22: Under unusual circumstances, flammable dust clouds occasionally appear and only exist for a short time or flammable dust occasionally accumulates or there may be a dust layer and a flammable dust air mixture is generated.